+高级检索
基于SLM的Ti-6Al-4V人工骨支架的结构设计
DOI:
作者:
作者单位:

新疆大学 机械工程学院,新疆大学 机械工程学院,新疆大学 机械工程学院,解放军兰州军区乌鲁木齐总医院全军骨科中心

作者简介:

通讯作者:

中图分类号:

TG146.2 3,TH122

基金项目:

国家自然科学基金项目(面上项目,重点项目,重大项目)


Structure Design of Ti-6Al-4V Artificial Bone Scaffold based on SLM
Author:
Affiliation:

School of Mechanical Engineering,Xinjiang University,Xinjiang Urumqi,School of Mechanical Engineering,Xinjiang University,Xinjiang Urumqi,School of Mechanical Engineering,Xinjiang University,Xinjiang Urumqi,Orthopedic Center of PLA,Urumqi General Hospital,Lanzhou Military Region,Xinjiang Urumqi

Fund Project:

National Key Basic Research Development Program of China (2011CB605502); Program of Introducing Talents of Discipline to Universities (08040)

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    设计了6种Ti-6Al-4V人工骨支架,利用SLM(选择性激光熔化)进行制备。采用万能材料实验机结合高速摄像机分析支架的压缩过程,并利用Ansys进行分析。结果表明:支架的立柱直径对支架的力学性能参数影响较大,横梁直径对其影响较小;在相同高度下,支架横梁直径增大、层数增多或立柱直径增大,均使结构长径比减小,使结构稳固且支架承载能力提高;支架的力学性能应与周围骨组织相匹配,经过分析,3种结构的支架力学性能参数与人体股骨相近,故可作为股骨的人工骨支架。

    Abstract:

    Six kinds of Ti-6Al-4V artificial bone scaffold were designed and built with SLM (Selective Laser Melting) technology. Universal material testing machine and high-speed camera were used to analyze the compression process of scaffolds, and ANSYS was used to analyze the stress of scaffold. The results showed that the vertical column diameter had a great influence on the mechanical property parameters of scaffolds but the beam diameter had little influence on them, under the same height, the increasing of beam diameter and layer or support column diameter, which result in structure length-diameter ratio decrease, so that structure firm and load-carrying capacity were improved and the mechanical property should match the surrounding bone tissue. Through the analysis, mechanical property parameters of three kinds of scaffolds were close to human femur, so they can be used as the artificial bone scaffolds of femur.

    参考文献
    相似文献
    引证文献
引用本文

杨文静,乌日开西.艾依提,王娟,滕勇.基于SLM的Ti-6Al-4V人工骨支架的结构设计[J].稀有金属材料与工程,2017,46(10):2993~2998.[Yang Wenjing, Wurikaixi AIYITI, Wang Juan, Teng Yong. Structure Design of Ti-6Al-4V Artificial Bone Scaffold based on SLM[J]. Rare Metal Materials and Engineering,2017,46(10):2993~2998.]
DOI:[doi]

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2015-07-08
  • 最后修改日期:2015-08-09
  • 录用日期:2015-09-07
  • 在线发布日期: 2017-12-01
  • 出版日期: