+高级检索
脉冲电压幅值与电解液流动状态对无掩模定域性电沉积微镍柱的影响
作者:
作者单位:

大连大学

作者简介:

通讯作者:

中图分类号:

基金项目:

国家自然科学基金资助(项目号51875071)


The Effect of Pulse Voltage Amplitude and Electrolyte Flow States on Manufacture of Micro Nickel Column by Mask-less Localized Electrochemical Deposition
Author:
Affiliation:

Dalian University

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    为探究脉冲电压幅值与电解液流动状态对无掩模定域性电沉积微镍柱的影响,采用体视显微镜和SEM扫描电子显微镜对电沉积的微镍柱进行观察、检测,并计算了平均沉积直径和速率。在实验的基础上通过控制变量法研究了脉冲电压幅值与电解液流动状态对沉积微镍柱平均直径、平均沉积速率和表面形貌的影响。研究表明,脉冲电压幅值越大,微镍柱沉积速率越大,表面形貌越粗糙;平均沉积直径和速率会随电解液流动状态变化而发生改变,沉积速率随电解液流速的增加而加快;液滴、微液滴和微射流状态下电压的增大会导致微镍柱沉积直径增大,冲击射流状态下电压的增大会导致微镍柱直径先增大后减小且微镍柱顶部呈明显的尖锥状并在镍柱周边存在“毛刺”;微镍柱的表面形貌随电解液流动状态的不同而不同,大流速喷射条件下,微镍柱表面更平整、致密。

    Abstract:

    In order to explore the influence of different electrolyte flow states on mask-less localized electrodeposition, the nickel column was detected by stereoscopic microscopy and scanning electron microscopy, and the average deposition diameter and rate were calculated. On the basis of experiments, the effects of pulse voltage amplitude and electrolyte flow states on average deposition diameter, average deposition rate and surface morphology of micro nickel column were studied by means of control variable method. The research shows that the higher pulse voltage amplitude leads to the greater deposition rate and rougher surface of the micro-nickel column. the average deposition diameter and rate will change with the change of electrolyte flow states, and the deposition rate will increase with the increase of the flow rate of the electrolyte. The increase of the voltage in droplet, droplet and micro-jet will lead to the increase of the deposition diameter of the micro-nickel column. In the impinging jet state, the diameter of the micro-nickel column will first increase and then decrease with the increase of the voltage. At the same time, the tip of the nickel column is obviously tapered and there are "burrs" around the nickel column. The surface of nickel column varies with the velocity of each injection mode. The surface of nickel column is denser under the condition of high velocity injection.

    参考文献
    相似文献
    引证文献
引用本文

钱宁开,吴蒙华,贾卫平,佐姗姗,王慧.脉冲电压幅值与电解液流动状态对无掩模定域性电沉积微镍柱的影响[J].稀有金属材料与工程,2021,50(3):918~923.[Qian Ningkai, Wu Menghua, Jia Weiping, Zuo Shanshan, Wang Hui. The Effect of Pulse Voltage Amplitude and Electrolyte Flow States on Manufacture of Micro Nickel Column by Mask-less Localized Electrochemical Deposition[J]. Rare Metal Materials and Engineering,2021,50(3):918~923.]
DOI:10.12442/j. issn.1002-185X.20200342

复制
文章指标
  • 点击次数:
  • 下载次数:
  • HTML阅读次数:
  • 引用次数:
历史
  • 收稿日期:2020-05-19
  • 最后修改日期:2020-06-04
  • 录用日期:2020-06-09
  • 在线发布日期: 2021-04-02
  • 出版日期: